How to read a well water test report
Last checked: November 26, 2026
A lab report can look like a wall of chemical names and numbers. Most reports follow the same pattern, though: each line shows what was tested, how much was found, the unit, and a limit to compare against. This guide walks through each piece and lists the EPA numbers most labs use as the yardstick.
1. Units: mg/L, µg/L and what they mean
- mg/L (milligrams per liter) is the same as ppm, parts per million.
- µg/L or ug/L (micrograms per liter) is the same as ppb, parts per billion. 1 mg/L = 1,000 µg/L.
- pCi/L (picocuries per liter) measures radioactivity, used for radium and some other radionuclides.
- Bacteria results are often reported as present/absent, or as a count per 100 mL.
Watch the units closely. Arsenic's limit is 0.010 mg/L, which is the same as 10 µg/L. A result of "8" means very different things depending on which unit the lab used.
2. "ND" and the reporting limit
"ND" or "<" followed by a number means the lab did not detect the substance above the lowest level its method can reliably measure (often called the reporting limit or detection limit). It doesn't prove the water contains zero, but it means any amount is below that level. Check that the reporting limit is lower than the standard you're comparing against.
3. The limits labs compare against
Private wells are not regulated by the federal Safe Drinking Water Act (USGS), but labs and health departments usually compare well results to the EPA standards for public water systems:
- MCL (Maximum Contaminant Level): the legal limit for public water systems, set for health reasons.
- MCLG (goal): the level below which there is no known or expected health risk. For some contaminants, like lead and arsenic, the goal is zero.
- Action level / TT: for lead and copper, EPA uses a treatment technique with an action level instead of an MCL.
- Secondary standards (SMCL): non-enforceable guidelines for taste, odor, color and staining, not health.
Some states set their own limits that are stricter than EPA's, so your report may cite a state standard. If it does, use that.
4. Health-based numbers you'll see most often
From the EPA National Primary Drinking Water Regulations:
| Contaminant | EPA limit | Common source |
|---|---|---|
| Total coliform / E. coli | Should be absent in a well sample (labs report present/absent) | Surface water, septic, animal waste |
| Nitrate (as N) | 10 mg/L | Fertilizer, septic systems, sewage, natural deposits |
| Nitrite (as N) | 1 mg/L | Same as nitrate |
| Arsenic | 0.010 mg/L (10 µg/L); goal is zero | Natural deposits, orchard runoff |
| Lead | Action level 0.015 mg/L (15 µg/L); goal is zero | Household plumbing corrosion, natural deposits |
| Copper | Action level 1.3 mg/L | Household plumbing corrosion |
| Fluoride | 4.0 mg/L | Natural deposits |
| Uranium | 30 µg/L | Natural deposits |
| Radium 226 + 228 (combined) | 5 pCi/L | Natural deposits |
| Mercury (inorganic) | 0.002 mg/L | Natural deposits, industrial discharge, landfills |
A note on coliform: CDC explains that coliforms themselves usually aren't harmful, but a positive result means germs that do cause illness may be getting in. A positive E. coli or fecal coliform result likely means human or animal waste has reached the well (CDC).
Nitrate above 10 mg/L is a particular concern for infants under six months, who can become seriously ill (EPA, same source). Talk to your health department about next steps.
5. Taste, odor and staining numbers
From EPA's secondary drinking water standards. These are guidelines for aesthetic problems, not health limits:
| Item | Guideline | What you notice above it |
|---|---|---|
| pH | 6.5 to 8.5 | Low: bitter metallic taste, corrosion. High: slippery feel, soda taste, deposits |
| Iron | 0.3 mg/L | Rusty color, sediment, metallic taste, reddish or orange staining |
| Manganese | 0.05 mg/L | Black to brown color, black staining, bitter metallic taste |
| Total dissolved solids | 500 mg/L | Hardness, deposits, colored water, staining, salty taste |
| Chloride | 250 mg/L | Salty taste |
| Sulfate | 250 mg/L | Salty taste |
| Copper | 1.0 mg/L | Metallic taste, blue-green staining |
| Fluoride | 2.0 mg/L | Tooth discoloration |
Low pH matters for more than taste: CDC notes acidic water can damage pipes and let metals like lead leach into your water. If your pH is low, a lead test is worth asking about.
6. What to do next
- Everything under the limits: keep the report, and retest on the schedule in our guide to what to test and how often.
- Bacteria present or a health-based limit exceeded: CDC suggests using bottled water or another safe source for drinking and contacting your local health or environmental department. They can help you understand the results and may suggest retesting.
- Only aesthetic problems: the water may be safe to drink but unpleasant or hard on fixtures. Treatment is optional and should match the specific problem.
- Not sure the lab is certified? Check your state's certification office through EPA's list of state lab certification contacts.